Atomic Absorption Spectrophotometer — PTM007
Atomic Absorption Spectrophotometer (AAS) is an analytical instrument used to determine the concentration of specific metal elements in a sample.
- PTM007: 190-900 nm
Condividi questo prodotto:
Scopo
Atomic Absorption Spectrophotometer (AAS) is an analytical instrument used to determine the concentration of specific metal elements in a sample.
Specifiche del prodotto
| Modello | PTM007 | ||
|---|---|---|---|
| PTM007 | 190-900 nm | ||
Alcune specifiche relative alle fonti o configurazioni dei modelli sono ancora in fase di revisione. Si prega di confermare il modello selezionato e le specifiche definitive al momento della richiesta di preventivo.
Prezzo
Richiedi un preventivo in base alle tue esigenze in termini di quantità, configurazione e consegna.
Descrizione del prodotto
Atomic Absorption Spectrophotometer (AAS) is an analytical instrument used to determine the concentration of specific metal elements in a sample. Its operation is based on the principle that free atoms in the gaseous state can absorb light at specific characteristic wavelengths.
The process begins by preparing a liquid sample, which is then aspirated into a high-temperature flame or graphite furnace. This heat atomizes the sample, breaking it down into ground-state, free atoms. The instrument simultaneously emits light from a hollow cathode lamp, which is designed to produce the precise wavelengths of light that the target metal atom can absorb. This beam of light passes through the cloud of atoms. The atoms of the specific element then absorb a fraction of this light, exciting their electrons to a higher energy level.
A monochromator then selects the characteristic wavelength and directs it to a detector, which measures the intensity of the light. The amount of light absorbed is directly proportional to the concentration of the element in the sample, as described by the Beer-Lambert law. By comparing the absorption to a calibration curve prepared from standards of known concentration, the instrument can accurately quantify the metal's presence.
AAS is renowned for its exceptional sensitivity, specificity, and reliability for over 60 metallic elements, including lead, mercury, copper, and zinc. It is a cornerstone technique in environmental monitoring, clinical toxicology, food safety, and metallurgy.

Need This Spectrophotometer for Your Laboratory?
Indicateci il tipo di campione, la capacità richiesta, la quantità e le vostre esigenze in termini di configurazione. Il nostro team vi aiuterà a individuare il modello più adatto e a preparare un preventivo.
Conferma i requisiti relativi alla candidatura e alle prestazioni
Verifica della configurazione, degli accessori e dell'alimentatore
Preparare un preventivo per la configurazione confermata
Coordinare le operazioni di imballaggio e spedizione
Discutere delle linee guida per l'installazione e dell'assistenza tecnica
Verifica i termini di garanzia e assistenza specifici per il modello